Comparing Latent Heat of Vaporization

Some of the largest deviations occur in the computation of the latent heat of vaporization, especially near the critical region. The results are summarized below:

Relative Error

IAPWS-97

NBS/NRC-84

IFC-67

Maximum absolute error

36.327%

60.610%

113.136%

Average absolute error

1.730%

2.165%

3.534%

Root Mean Square error

6.534%

8.304%

15.311%

Note: The IAPWS-95 formulation is used as the baseline for comparisons.